产品类别

LOGO!逻辑模块
SIMATIC S7-1200基本控制器
SIMATIC S7-1500基本控制器
常规SINAMICS G 变频器
SINAMICS S120 驱动系统
V90 伺服电机
1PH8 异步电机
1PH8 伺服电机 (同步)
电源电缆 (预装/原装线缆)
信号电缆 (预装/原装线缆)
1FT7 伺服电机
1FK7 伺服电机
1FK2 伺服电机
SIMOTICS L 直线电机
SIMOTICS T 扭矩电机
SIMOTICS S-1FG1 伺服齿轮电机
电机主轴
驱动技术其他部件
SIMATIC HMI 控制和监视系统
SIMATIC HMI 附件
SIMATIC HMI 软件
低压电机(标准工业电机)
低压大功率电机
其他产品

相关下载

产品筛选

订购咨询

 > 5SY8220-7 > 返回

Product

现货推荐产品

Product
Article Number (Market Facing Number) 5SY8220-7
Product Description Miniature circuit breaker 400 V D=70 mm 25 kA according to EN 60947-2, 2P, C20
Product family Basic Devices
Product Lifecycle (PLM) PM300:Active Product
Price data
Price Group SW
List Price (w/o VAT) Show prices
Customer Price Show prices
Metal Factor L-O-----
Delivery information
Export Control Regulations AL : N / ECCN : N
Factory Production Time 15 Day/Days
Net Weight (kg) 0.321 Kg
Packaging Dimension 40.00 x 92.00 x 84.00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1
Additional Product Information
EAN 4001869263366
UPC Not available
Commodity Code 85362010
LKZ_FDB/ CatalogID LV10.1
Product Group 5525
Group Code P310
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 10.01.2006
Returnable No
WEEE (2012/19/EU) Take-Back Obligation -
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

SCIP number
Classifications
 
Version Classification
eClass 12 27-14-19-01
eClass 14 27-14-19-01
eClass 6 27-14-19-01
eClass 7.1 27-14-19-01
eClass 8 27-14-19-01
eClass 9 27-14-19-01
eClass 9.1 27-14-19-01
ETIM 7 EC000042
ETIM 8 EC000042
ETIM 9 EC000042
UNSPSC 15 39-12-16-03

相关配套产品

5ST3010
  • auxiliary switch, 1 NO+1 NC for miniature circuit breaker 5SL, 5SY, 5SP Incorporated switch 5TL1, RCBO 5SU1, FI 5SV (for 5SU1 handle coupler 5ST3805-1 is required)
5ST3801
  • handle locking devices for miniature circuit breaker for 5SY (not for 5SY17...) 5SP, 5TE8, 5SJ4...-.HG..
5ST3803
  • locking device with bracket lock for miniature circuit breaker D=70 mm (1 set in poly bag) for 5SY, 5SP, 5TE8, 5SJ4...-.HG..
5ST3807
  • locking device with bracket lock (1 set in poly bag) for 5SL, 5SV, 5TL1
5SW3006
  • Wall box, gray IP40, for flush mounting for built-in devices 2, 5 MW max. wide
5SW3007
  • Wall box, gray IP40, for flush mounting for built-in devices 4, 5 MW max. wide
5SW1200
  • Molded-plastic enclosure SM, 4, 5 MW for RC and miniature circuit breaker
5TG8240
  • Spacer 0.5 MW
5ST3020
  • Fault signal contact 1 NO+1 NC, for miniature circuit breaker 5SL, 5SY, 5SP RCBO 5SU1, FI 5SV (for 5SU1 handle coupler 5ST3805-1 is required)
5ST3030
  • shunt release 110-415 V AC, for miniature circuit breaker 5SL4, 5SY, 5SP, RCBO 5SU1, FI 5SV (for 5SU1 handle coupler 5ST3805-1 is required)
5ST3040
  • Undervoltage release 230 V AC, with 6 terminals for miniature circuit breaker 5SL4, 5SY, 5SP RCBO 5SU1, FI 5SV (for 5SU1 handle coupler 5ST3805-1 is required)
5ST3062
  • Auxiliary switch changeover contact and Fault signal contact changeover contact 0.5 MW 230/400 V AC 24-220 V DC for 5SY, 5SL for 5SP, 5SV, 5SU1, 5ST3
5ST3062-0MC
  • 5ST3 COM auxiliary switch + fault signal contact, 0,5 MW for MCB, RCCB, RCBO, AFDD Disconnector 5TL1 Remote control mechanism Power supply DC 24V Please consider Radio approval! List of countries: see Certificates
5ST3053
  • remote operating mechanism 5ST3 Basic 12-30 V AC / 12-48 V DC; 1.5 MW; for CB, RCBO up to 3-pole, ON/OFF switch
5ST3820-1
  • Adapter for 5SY 1 to 2MW for LS 5SY, 5SY..KK Accessory for remote operating mechanism
5ST3071
  • Remote Control Auxiliary power with extended features (railway, temperature), 230V AC, 110V DC; 2MW; for MCB up to 4P, RCCB, RCBO
5ST3800
  • terminal cover 1-pole for miniature circuit breakers,
5SW3004
  • terminal cover, gray IP40, for surface mounting for built-in devices 2, 5 MW max. wide
5SW3005
  • terminal cover, gray IP40, for surface mounting for built-in devices 4, 5 MW max. wide
5SW3011
  • Terminal cover for residual current operated circuit breaker 5SM1 2, 5 MW
5ST3073-0MC
  • remote operating mechanism 5ST3 COM with communication, RCD/IR test and ARD; 100-240 V AC; 2.5 MW; for CB, RCCB, RC units, RCBO, ON/OFF switch, Please consider wireless approval! list of countries: see certificates
5ST1317
  • TERMINAL COVER FOR MAIN-M.C.B BY Z-PLACES 125MM DISTANCE
5ST2200
  • TERMINAL COVER CAP FOR 5SQ MCB
5ST3060
  • rotary operating mechanism compl. black for 5SY, 5SP4, 5SL, 5TL1, 5TE2 and 5SU1 from 2 modular widths
5ST3061
  • rotary operating mechanism compl. red for 5SY, 5SP4, 5SL, 5TL1, 5TE2 and 5SU1 from 2 modular widths
5ST1316
  • Terminal covers for Main miniature circuit breaker (SHU), for terminal cover within the sleeve dimension
5SM2322-0
  • RC unit for 5SY, 2-pole, type AC, In: 40 A, 30 mA, Un AC: 230 V
5SM2322-3
  • RC unit for 5SY, 2-pole, type F, short-time delayed, In: 40 A, 30 mA, Un AC: 230 V
5SM2322-6
  • RC unit for 5SY, 2-pole, type A, In: 40 A, 30 mA, Un AC: 230 V
5SM2322-6KK01
  • RC unit for 5SY, 2-pole, type A, short-time delayed, In: 40 A, 30 mA, Un AC: 230 V
5SM2622-0
  • RC unit for 5SY, 2-pole, type AC, In: 40 A, 300 mA, Un AC: 230 V
5SM2622-2
  • RC unit for 5SY, 2-pole, type AC, selective, In: 40 A, 300 mA, Un AC: 230 V
5SM2622-6
  • RC unit for 5SY, 2-pole, type A, In: 40 A, 300 mA, Un AC: 230 V
5SM2622-8
  • RC unit for 5SY, 2-pole, type A, selective, In: 40 A, 300 mA, Un AC: 230 V
5SM2822-8
  • RC unit for 5SY, 2-pole, type A, selective, In: 40 A, 1000 mA, Un AC: 230 V
5SM2325-0
  • RC unit for 5SY, 2-pole, type AC, In: 63 A, 30 mA, Un AC: 230 V
5SM2325-3
  • RC unit for 5SY, 2-pole, type F, short-time delayed, In: 63 A, 30 mA, Un AC: 230 V
5SM2325-6
  • RC unit for 5SY, 2-pole, type A, In: 63 A, 30 mA, Un AC: 230 V
5ST3608
  • Pin busbar, 10 mm2 connection: 6x 2-phase touch-safe
5ST3623
  • Pin busbar, 10 mm2 connection: 2x3x (1-phase+N) touch-safe
5ST3653
  • Pin busbar, 16 mm2 connection: 2x3x (1-phase+N) touch-safe
5ST3704
  • Pin busbar touch-safe, 16 mm2 2-phase, 214 mm long can be cut, with end caps
5ST3642
  • Pin busbar, 16 mm2 connection: 5x (2-phase+AUX/FS) touch-safe
5ST3624
  • Pin busbar, 10 mm2 connection: 3-phase/N+8x phase touch-safe for 1F, 4-pole + 8 CB, 1-pole
5ST3635
  • Pin busbar, 16 mm2 connection: 9X (1-phase+AUX/FS) touch-safe
5ST3654
  • Pin busbar, 16 mm2 connection: 3-phase/+ 8x phase touch-safe for 1F, 4-pole + 8 CB, 1-pole
5ST3786-0
  • compact Pin Busbar, 10mm2 connection: 1p/N AFDD 5SM6 + RCBO 2-pole + auxiliary switch 0.5 MW touch protected 1000mm cuttable
5ST3772
  • BB 2-phase 16 mm2,for FI5SV(1+N) and 5x(AFDD 5SM601+CB SY60), fixed length 216 mm
5ST3735-2
  • Pin busbar, 2-phase 10 mm2, 990mm, gray insulation can be cut for FI/LS 2P (3 MW)+AFDD
5ST3610
  • Pin busbar, 10 mm2 connection: 2x (2-phase+AUX/FS) touch-safe
5ST3611
  • Pin busbar, 10 mm2 connection: 3x (2-phase+AUX/FS) touch-safe
5ST3612
  • Pin busbar, 10 mm2 connection: 5x (2-phase+AUX/FS) touch-safe
5ST3640
  • Pin busbar, 16 mm2 connection: 2x (2-phase+AUX/FS) touch-safe
5ST3641
  • Pin busbar, 16 mm2 connection: 3x (2-phase+AUX/FS) touch-safe
5ST3706
  • Pin busbar touch-safe, 16 mm2 2-phase+AUX, 214 mm long can be cut, with end caps
5ST3707
  • Pin busbar touch-safe, 16 mm2 2-phase+AUX, 1016 mm long can be cut, without end caps
5ST3736
  • Pin busbar touch-safe, 10 mm2 2-phase+AUX, 214 mm long can be cut with end caps
5ST3737
  • Pin busbar touch-safe, 10 mm2 2-phase+AUX, 1016 mm long can be cut, without end caps
5ST3606
  • Pin busbar, 10 mm2 connection: 2x 2-phase touch-safe
5ST3607
  • Pin busbar, 10 mm2 connection: 3x 2-phase touch-safe
5ST3636
  • Pin busbar, 16 mm2 connection: 2x 2-phase touch-safe
5ST3637
  • Pin busbar, 16 mm2 connection: 3x 2-phase touch-safe
5ST3638
  • Pin busbar, 16 mm2 connection: 6x 2-phase touch-safe
5ST3623-4
  • Pin Busbar, 10mm2 connection: 3p/N 7x MCB 2-pole touch protected 14MW fixed length
5ST3625-4
  • Pin Busbar, 10mm2 connection: 3p/N (RCCB N-right) 1x RCCB 4-pole + 5x MCB 2-pole touch protected 14 MW fixed length
5ST3725-3
  • Pin Busbar, 10mm2 connection: 3p/N (RCCB N-right) 1x RCCB 4-pole +1x MCB 3-pole+ 3x MCB 2-pole touch protected 13 MW fixed length
5ST3725-4
  • Pin Busbar, 10mm2 connection: 3p/N (RCCB N-right) 1x RCCB 4-pole +1x MCB 4-pole+ 3x MCB 2-pole touch protected 14 MW fixed length
5ST3705
  • Pin busbar touch-safe, 16 mm2 2-phase, 1016 mm long can be cut, without end caps
5ST3734
  • Pin busbar touch-safe, 10 mm2 2-phase, 214 mm long can be cut, with end caps
5ST3735
  • Pin busbar touch-safe, 10 mm2 2-phase, 1016 mm long can be cut, without end caps
5ST3735-1
  • Pin busbar, 2-phase 10 mm2, 56 MW, gray insulation can be cut for AFDD 5SM602.-2
5ST3770-6
  • Pin busbar touch-safe, 16 mm2 1-phase+N, 12 MW fully insulated
5ST3770-7
  • Pin busbar touch-safe, 16 mm2 1-phase+N, 1000 mm long without end caps
5ST3770-8
  • Pin busbar touch-safe, 16 mm2 1-phase+N, 12 MW fully insulated
5ST3771-0
  • Pin busbar touch-safe, 16 mm2 1-phase+N, 1000 mm long without end caps
5ST3624-1
  • Pin Busbar, 10mm2 connection: 3p (RCCB N-right) 1x RCCB 4-pole + 6x MCB 1-pole touch protected 10 MW fixed length
5ST3624-4
  • Pin Busbar, 10mm2 connection: 3p (RCCB N-right) 1x RCCB 4-pole + 10x MCB 1-pole touch protected 14 MW fixed length

微信咨询请扫码